Liberty Test   Call Us: 877-821-4811  
 
  Home | Product Categories | Brands | Doing Business | Current Promotions | Lab | Solutions | About | Contact Us
 
 
ALL BRANDS
ALL EQUIPMENT
FEATURED PRODUCTS
SPECIALS
                    
Home : Equipment > Oscilloscopes > 204MXi-A
Teledyne LeCroy 204MXi-A 2 GHz, 5 GS/s, 4ch, 12.5Mpts/Ch DSO with 10.4" Color Touch Screen Display

2 GHz, 5 GS/s, 4ch, 12.5Mpts/Ch DSO with 10.4

Product Status: New / Refurbished
List Price: $21,105
Our Price: Request Quote
Rental Price: Request Quote

Download project datasheet details pdf file  Download Datasheet
Click here to view enlarge image
SPECIFICATIONS

The LeCroy WaveRunner Xi-A is the most powerful and capable scope available in its class. Basic system validation using advanced triggers, fast viewing modes, measurement parameters, or serial decodes is simple and easy. Advanced debug, multi-domain analysis, and waveshape analysis are possible with tools unique to WaveRunner Xi-A. Optional application packages help you make sense of well-defined problems.
  • Trigger on I2C, SPI, UART, RS-232, AudioBus (I2S, LJ, RJ, TDM), LIN, CAN, or FlexRay or MIL-STD-1553 serial data patterns. Intuitively decode values on the oscilloscope grid.
  • Use the high sampling rate and WaveStream fast viewing mode to characterize signal shape, rise time, overshoot, etc., and verify the presence or absence of high-speed transients.
  • Sequence Mode allows you to partition your acquisition memory into segments and capture specific events over long periods of time. Then, view and analyze each segment individually.
  • Search and Analysis WaveScan provides the ability to locate unusual events in a single capture, or scan for an event in many acquisitions over a long period of time using more than 20 different search/scan modes. Use ScanHisto or ScanOverlay to display intuitive scanned results.
  • Quickly create your own measurement parameters or math functions using Excel, MATLAB®, or VBScripts (some capability optional).
  • WaveRunner Xi-A's long memory is optimized for calculation of more information 10–100x faster than other oscilloscopes, while enabling easy access to simple zooming and positioning from the front panel.
  • Amplify your understanding with multidomain analysis of your signals. Convert signal information into Statistical domain (Histogram), Spectral domain (long memory FFTs), Jitter, Modulation, or other Measurement Parameter domains (Tracks of measurement parameters). (Some capability is optional.)
  • Excellent overdrive recovery and signal integrity make WaveRunner Xi-A ideal for high-voltage switching loss, conduction loss, ripple, switching power supply, and other amplifier measurements. Use with LeCroy Differential Amplifiers for highperformance 100,000:1 Common Mode Rejection Ratio.
  • Extensive triggers allow fast event isolation. Measure timing statistically and view behavior graphically using histograms. Gain real understanding of root cause.
  • Long memory, HFREJ trigger coupling, built-in noise filtering, etc. enable fast understanding of signal behavior in circuits with a mix of slow-speed (sensor, actuator, power supply, mechanical) and high-speed signals.
IN-STOCK EQUIPMENT
204MXi-A /VL/WRXi~JTA2/WRXi~XDEV/WRXi~XMAP/WRXi~XMATH
 
AVAILABLE EQUIPMENT OPTIONS
CANbus TD CANbus TD Trigger and Decode
CANbus TDM CANbus TDM Trigger, Decode, and Measure/Graph
ET~PMT Electrical Telecom Mask Test Package
QPHY~ENET QualiPHY Enabled Ethernet Software Option. * TF-ENET-B required
QPHY~USB QualiPHY Enabled USB 2.0 Software Option. * TF-USB-B required.
TF~ENET~B 10/100/1000Base-T Compliance Test Fixture. Includes ENET-2CAB-SMA018 and ENET-2ADA-BNCSMA
TF~USB~B USB 2.0 Compliance Test Fixture
VL Memory Options
WRXi~1553 TD MIL-STD-1553 Trigger and Decode
WRXi~A~RHD Removable Hard Drive Package (Includes removeable hard drive kit and two hard drives)
WRXi~A~RHD~02 Additional Removable Hard Drive
WRXi~Audiobus TD Audiobus Trigger and Decode for I2S, LJ, RJ, and TDM
WRXi~Audiobus TDG Audiobus Trigger, Decode, and Graph for I2S LJ, RJ, and TDM
WRXi~DDM2 Disk Drive Measurement Software Package
WRXi~DFP2 Digital Filter Software Package
WRXi~EMC EMC Pulse Parameter Software Package
WRXi~FlexRaybus TD FlexRay Trigger and Decode
WRXi~FlexRaybus TDP FlexRay Trigger and Decode Physical Layer Test
WRXi~HARDCASE Hard Transit Case
WRXi~I2Cbus TD I2C Trigger and Decode
WRXi~JTA2 Jitter and Timing Analysis Software Package (Standard with MXi-A model oscilloscopes)
WRXi~KYBD Mini Keyboard
WRXi~LINbus TD LIN Trigger and Decode
WRXi~MS~CLAMP Mounting Stand – Desktop Clamp Style
WRXi~PMA2 PowerMeasure Analysis Software Package
WRXi~RACK Rackmount Kit
WRXi~SDM Serial Data Mask Software Package
WRXi~SOFTCASE Soft Carrying Case
WRXi~SPECTRUM Spectrum Analyzer and Advanced FFT
WRXi~SPIbus TD SPI Trigger and Decode
WRXi~STAT Statistics Software Package
WRXi~UART~RS232bus TD UART and RS-232 Trigger and Decode
WRXi~XDEV Advanced Customization Software Package (Standard with MXi-A model oscilloscopes)
WRXi~XMAP Master Analysis Software Package (Standard with MXi-A model oscilloscopes)
WRXi~XMATH Advanced Math Software Package (Standard with MXi-A model oscilloscopes)
WRXi~XVAP Value Analysis Software Package (Includes XWAV and JTA2) (Standard with MXi-A model oscilloscopes)
WRXi~XWAV Intermediate Math Software Package (Standard with MXi-A model oscilloscopes)
WRXi~XWEB Processing Web Editor Software Package
WS~GPIB External GPIB Interface

Recently Viewed Items
204MXi-A
Teledyne LeCroy
Clear List
 
Keysight Technologies Tektronix Fluke Krohn-Hite Teledyne LeCroy