The precision multiple output, 25W - 50W GPIB 6625A, 6626A, 6628A, and 6629A provide fast, low-noise outputs; dual-range, precision low current measurement; built-in measurements and advanced programmable features; and protection features to ensure DUT safety. The Agilent 50W, four-output 6629A is a versatile solution help improve system accuracy and reduce test time in a 3U high package. Output Ratings (4 outputs): - Low-range volts, amps 50W: 0 to 16 V, 0 to 200 mA
- High range volts, amps 50W: 0 to 50 V, 0 to 1 A or 0 to 16 V, 0 to 2 A
Programming Accuracy (4 outputs): - Voltage 50W: 3 mV + 0.016% (low), 10 mV + 0.016% (high)
- Current 50W: 185 µA + 0.04% (low), 500 µA + 0.04% (high)
Ripple & Noise (4 outputs): - Constant voltage rms: 500 µV
- Peak-to-peak: 3 mV
- Constant current rms: 0.1 mA
Readback Accuracy (4 outputs): - Voltage 50W: 0.016% + 3.5 mV (low), 0.016% + 10 mV (high)
- +/-Current 50W: 0.04% + 250 µA (low), 0.04% + 550 µA (high)
|